Fluke 107 Palm-sized, CAT III Digital Multimeter | Toko Maritim

Pemilik / Toko : Asia Industri
07/Jun/2022
Rp. 1.680.000 1.680.000 Kondisi : Baru

Fluke 107 Palm-sized, CAT III Digital Multimeter

  • Berat : 600 g
  • Stok :
  • Kondisi :Baru
  • Size / Ukuran :
  • COD : Cash on Delivery available

Perumahan Mahkota Simprug Blok B14 No.6, RT.004/RW.016,…

BANTEN


Telpon Whatsapp Toko Details

Fluke 107 Palm-sized, CAT III Digital Multimeter


Features

·         CAT III 600 V safety rating

·         Current and voltage measurements

·         Measures resistance and continuity to check for broken wires

·         Data hold and backlit display to keep you working safe and fast


Specifications

AC volts (40 Hz to 500Hz) :

- Range : 600 V

- Resolution : 0.001 V

- Accuracy : 1.0% + 3

DC volts :

- Range : 600 V

- Resolution : 0.001 V

- Accuracy : 0.5% + 3

Exchange millivolts :

- Range : 600 mV

- Resolution : 0.1 mV

- Accuracy : 3.0 % + 3

Diode Test :

- Range : 2 V

- Resolution : 0.001 V

- Accuracy : 10%

Resistance (Ohms) :

- Range : 40 MΩ

- Resolution : 0.1 Ω

- Accuracy : 0.5% + 3

Capacitor :

- Range : 1000 μF

- Resolution : 0.01 nF

- Accuracy : 2 % + 5

Frequency Hz (10 Hz – 100 kHz) :

- Range : 100 kHz

- Resolution : 0.01 Hz

- Accuracy : 0.1 % + 3

Duty Cycle :

- Range : 1% to 99%

- Resolution : 0.1%

- Accuracy : 1% typical case

AC current (40 Hz to 200 Hz) :

- Range : 10 A

- Resolution : 0.001 A

- Accuracy : 1.5% + 3

DC :

- Range : 10 A

- Resolution : 0.001 A

- Accuracy : 1.5% + 3

AC volts :

- Overload protection : 600 V

- Input impedance (Nominal) : >10 MΩ <100>

- Common mode rejection ratio : >60 dB at dc, 50 Hz or 60 Hz

AC millivolts :

- Overload protection : 600 mV

- Input impedance (Nominal) : >1MΩ, <100>

- Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz

DC volts :

- Overload protection : 600 V

- Input impedance (Nominal) : >10 MΩ <100>

- Common mode rejection ratio : >100 dB at dc, 50 Hz or 60 Hz

- Normal mode rejection ratio : >60 dB at 50 Hz or 60 Hz

DC millivolts :

- Overload protection : 400 mV

- Input impedance (Nominal) : >1MΩ, <100>

- Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz

General specifications

Maximum voltage between any terminal and earth ground : 600 V

Display (LCD) : 6000 counts, updated three times per second

Battery type : 2 AA, NEDA 24A, IEC LR03

Battery life : 200 hours minimum

Temperature

- Operating : 0 °C to 40 °C

- Storage : -30 °C to 60 °C

Relative Humidity

Operating Humidity : Non-condensing when <10>

Operating Humidity, 40 MΩ Range : ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C

Altitude : 2000 m, Storage : 12,000 m

Temperature coefficient : 0.1 X (specified accuracy) /°C (<18>28 °C)

Fuse protection for current inputs : 11A, 1000V Fast Fuse, Fluke specified part only

Size (H x W x L) : 142 x 69 x 28 mm

Weight : 200 g

IP rating : IP 40

Safety : IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2

Electromagnetic environment : IEC 61326-1: Portable

Includes : TL75 test leads with two caps, 2 AA batteries, User’s manual

===========================================================

UNTUK MENGHINDARI PESANAN BARANG ANDA DITOLAK OLEH KAMI, SILAHKAN BERTANYA STOCK BARANG TERLEBIH DAHULU. TERIMA KASIH

Untuk informasi dan pemesanan, silahkan menghubungi :

Telp. & WA : 62.813.3117.0440

Mail : asiaindustri@gmail.com

============================================================

 

 