Fluke 106
Palm-sized Digital Multimeter
Features
·
Voltage,
resistance, continuity, capacitance
·
Input terminal for
ac and dc current measurements to 10 A and current
·
Data hold
Specifications
AC volts (40
Hz to 500Hz) :
- Range : 600 V
- Resolution : 0.001 V
- Accuracy : 1.0% + 3
DC volts :
- Range : 600 V
- Resolution : 0.001 V
- Accuracy : 0.5% + 3
AC
millivolts :
- Range : 600 mV
- Resolution : 0.1 mV
- Accuracy : 3.0% + 3
Diode Test
:
- Range : 2 V
- Resolution : 0.001 V
- Accuracy : 10%
Resistance
(Ohms) :
- Range : 40 MΩ
- Resolution : 0.1 Ω
- Accuracy : 0.5% + 3
Capacitance
:
- Range : 1000 μF
- Resolution : 0.01 nF
- Accuracy : 2% + 5
Frequency
Hz (10 Hz – 100 kHz) :
- Range : 100 kHz
- Resolution : 0.01 Hz
- Accuracy : -
Duty Cycle
:
- Range : 1% to 99%
- Resolution : 0.1%
- Accuracy : -
AC current
μA (40 Hz to 200 Hz) :
- Range : 10 A
- Resolution : 0.001 A
- Accuracy : 1.5% + 3
DC current
:
- Range : 10 A
- Resolution : 0.001 A
- Accuracy : 1.5% + 3
AC volts :
- Overload protection : 600 V
- Input impedance (Nominal) : >10 MΩ <100>
- Common mode rejection ratio : >60 dB at dc, 50 Hz or 60 Hz
AC
millivolts :
- Overload protection : 600 mV
- Input impedance (Nominal) : >1MΩ, <100>
- Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz
DC volts :
- Overload protection : 600 V
- Input impedance (Nominal) : >10 MΩ <100>
- Common mode rejection ratio : >100 dB at dc, 50 Hz or 60 Hz
- Normal mode rejection ratio : >60 dB at 50 Hz or 60 Hz
DC
millivolts :
- Overload protection : 400 mV
- Input impedance (Nominal) : >1MΩ, <100>
- Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz
General
specifications
Maximum voltage between any terminal and earth ground : 600 V
Display (LCD) : 4000 counts, updates 3/sec
Battery type : 2 AA, NEDA 24A, IEC LR03
Battery life : 200 hours minimum
Temperature
- Operating : 0 °C to 40 °C
- Storage : -30 °C to 60 °C
Relative
Humidity
Operating Humidity : Non-condensing when <10>
Operating Humidity, 40 MΩ Range : ≤80 % at 10 °C to 30 °C; ≤70 %
at 30 °C to 40 °C
Altitude : 2000 m, Storage : 12,000 m
Temperature coefficient : 0.1 X (specified accuracy) /°C (<18>28 °C)
Fuse protection for current inputs : 11A, 1000V Fast Fuse, Fluke
specified part only
Size (H x W x L) : 142 x 69 x 28 mm
Weight : 200 g
IP rating : IP 40
Safety : IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V,
Pollution Degree 2
Electromagnetic environment : IEC 61326-1: Portable
Includes : TL75 test leads with two caps, 2 AA batteries, User’s
manual
===========================================================