Fluke 106 Palm-sized Digital Multimeter
Features
· Voltage, resistance, continuity, capacitance
· Input terminal for ac and dc current measurements to 10 A and current
· Data hold
Specifications
AC volts (40 Hz to 500Hz) :
- Range : 600 V
- Resolution : 0.001 V
- Accuracy : 1.0% + 3
DC volts :
- Range : 600 V
- Resolution : 0.001 V
- Accuracy : 0.5% + 3
AC millivolts :
- Range : 600 mV
- Resolution : 0.1 mV
- Accuracy : 3.0% + 3
Diode Test :
- Range : 2 V
- Resolution : 0.001 V
- Accuracy : 10%
Resistance (Ohms) :
- Range : 40 MΩ
- Resolution : 0.1 Ω
- Accuracy : 0.5% + 3
Capacitance :
- Range : 1000 μF
- Resolution : 0.01 nF
- Accuracy : 2% + 5
Frequency Hz (10 Hz – 100 kHz) :
- Range : 100 kHz
- Resolution : 0.01 Hz
- Accuracy : -
Duty Cycle :
- Range : 1% to 99%
- Resolution : 0.1%
- Accuracy : -
AC current μA (40 Hz to 200 Hz) :
- Range : 10 A
- Resolution : 0.001 A
- Accuracy : 1.5% + 3
DC current :
- Range : 10 A
- Resolution : 0.001 A
- Accuracy : 1.5% + 3
AC volts :
- Overload protection : 600 V
- Input impedance (Nominal) : >10 MΩ <100>
- Common mode rejection ratio : >60 dB at dc, 50 Hz or 60 Hz
AC millivolts :
- Overload protection : 600 mV
- Input impedance (Nominal) : >1MΩ, <100>
- Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz
DC volts :
- Overload protection : 600 V
- Input impedance (Nominal) : >10 MΩ <100>
- Common mode rejection ratio : >100 dB at dc, 50 Hz or 60 Hz
- Normal mode rejection ratio : >60 dB at 50 Hz or 60 Hz
DC millivolts :
- Overload protection : 400 mV
- Input impedance (Nominal) : >1MΩ, <100>
- Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz
General specifications
Maximum voltage between any terminal and earth ground : 600 V
Display (LCD) : 4000 counts, updates 3/sec
Battery type : 2 AA, NEDA 24A, IEC LR03
Battery life : 200 hours minimum
Temperature
- Operating : 0 °C to 40 °C
- Storage : -30 °C to 60 °C
Relative Humidity
Operating Humidity : Non-condensing when <10>
Operating Humidity, 40 MΩ Range : ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C
Altitude : 2000 m, Storage : 12,000 m
Temperature coefficient : 0.1 X (specified accuracy) /°C (<18>28 °C)
Fuse protection for current inputs : 11A, 1000V Fast Fuse, Fluke specified part only
Size (H x W x L) : 142 x 69 x 28 mm
Weight : 200 g
IP rating : IP 40
Safety : IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment : IEC 61326-1: Portable
Includes : TL75 test leads with two caps, 2 AA batteries, User’s manual
===========================================================
UNTUK MENGHINDARI PESANAN BARANG ANDA DITOLAK OLEH KAMI, SILAHKAN BERTANYA STOCK BARANG TERLEBIH DAHULU. TERIMA KASIH
Untuk informasi dan pemesanan, silahkan menghubungi :
Telp. & WA : 62.813.3117.0440
Mail : asiaindustri@gmail.com
============================================================
Empty
Packaging & Delivery
Empty too
Asia Industri
Perumahan Mahkota Simprug Blok B14 No.6, RT.004/RW.016,…
BANTEN