Fluke 369 True-RMS Leakage Current Clamp Meter | Toko Maritim

Pemilik / Toko : Asia Industri
30/May/2022
Rp. 18.600.000 18.600.000 Kondisi : Baru

Fluke 369 True-RMS Leakage Current Clamp Meter

  • Berat : 900 g
  • Stok :
  • Kondisi :Baru
  • Size / Ukuran :
  • COD : Cash on Delivery available

Perumahan Mahkota Simprug Blok B14 No.6, RT.004/RW.016,…

BANTEN


Telpon Whatsapp Toko Details

Fluke 369 True-RMS Leakage Current Clamp Meter

============================================================

Features

·         True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms

·         61 mm jaw opening

·         Highest resolution of 1 μA, measure up to 60 A

·         Selectable filter function removes unwanted noise

·         Max/Min/Average readings and hold function

·         Forward-facing LED worklight for use in dark wiring cabinets

·         Backlit display; auto backlight off and auto power off for extended battery life

·         CAT III 600V safety rating

============================================================

Specifications

Electrical Specifications

Measurement function : Alternating current

AC ampere range : 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A

Range selection :

- mA / A : manual selection

- 3 mA / 30 mA / 300 mA : automatic selection

- 3 A / 30 A / 60 A : automatic selection

Range / Resolution :

- 3 mA¹ / 0.001 mA

- 30 mA / 0.01 mA

- 300 mA / 0.1 mA

- 3 A / 0.001 A

- 30 A / 0.01 A

- 60 A / 0.1 A

Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)² : 3 mA – 30 A (1% + 5 digits), 60 A (2% + 5 digits)

Frequency : 40 Hz to 1 kHz

Crest Factor : 3

Physical

Display (LCD) : Digital readout: 3300 count

Display refresh rate : 4 times / sec

Maximum conductor diameter : 61 mm

Dimensions : 257 x 116 x 46 mm

Weight : 600 g

Battery : 2 AA, IEC LR6, NEDA 15A, alkaline

Battery life : Expected battery life, without using backlight and spotlight, is more than 150 hours

Automatic shut-down : Meter automatically shuts down after 15 minutes of inactivity

Safety and Environmental Specifications

General safety : IEC 61010-1: Pollution Degree 2

Measurement safety : IEC 61010-2-032: CAT III 600 V / CAT IV 300 V

Operating temperature : -10 °C to +50 °C

Storage temperature : -40 °C to +60 °C

Operating humidity : Non-condensing (<10>

Protection class : IEC 60529: IP30 (jaw closed)

Operating altitude : 2000 m

Storage altitude : 12000 m

Current sensor action category : IEC 61557-13: Class 2, ≤30 A / m

Electromagnetic compatibility (EMC)

International

IEC 61326-1 : Industrial Electromagnetic Environment

CISPR 11 : Group 1 Class B

Group 1 : Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.

Class B : Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements. Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)

Class A : This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment. USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Included : Leakage Clamp Meter, Soft case, Safety Manual, Batteries: 2 AA

===========================================================

UNTUK MENGHINDARI PESANAN BARANG ANDA DITOLAK OLEH KAMI, SILAHKAN BERTANYA STOCK BARANG TERLEBIH DAHULU. TERIMA KASIH

Untuk informasi dan pemesanan, silahkan menghubungi :

Telp. & WA : 62.813.3117.0440

Mail : asiaindustri@gmail.com

============================================================

 



Empty

Packaging & Delivery


Empty too

Empty

Related products