Fluke 369 True-RMS Leakage Current Clamp Meter
============================================================
Features
· True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms
· 61 mm jaw opening
· Highest resolution of 1 μA, measure up to 60 A
· Selectable filter function removes unwanted noise
· Max/Min/Average readings and hold function
· Forward-facing LED worklight for use in dark wiring cabinets
· Backlit display; auto backlight off and auto power off for extended battery life
· CAT III 600V safety rating
============================================================
Specifications
Electrical Specifications
Measurement function : Alternating current
AC ampere range : 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
Range selection :
- mA / A : manual selection
- 3 mA / 30 mA / 300 mA : automatic selection
- 3 A / 30 A / 60 A : automatic selection
Range / Resolution :
- 3 mA¹ / 0.001 mA
- 30 mA / 0.01 mA
- 300 mA / 0.1 mA
- 3 A / 0.001 A
- 30 A / 0.01 A
- 60 A / 0.1 A
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)² : 3 mA – 30 A (1% + 5 digits), 60 A (2% + 5 digits)
Frequency : 40 Hz to 1 kHz
Crest Factor : 3
Physical
Display (LCD) : Digital readout: 3300 count
Display refresh rate : 4 times / sec
Maximum conductor diameter : 61 mm
Dimensions : 257 x 116 x 46 mm
Weight : 600 g
Battery : 2 AA, IEC LR6, NEDA 15A, alkaline
Battery life : Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-down : Meter automatically shuts down after 15 minutes of inactivity
Safety and Environmental Specifications
General safety : IEC 61010-1: Pollution Degree 2
Measurement safety : IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Operating temperature : -10 °C to +50 °C
Storage temperature : -40 °C to +60 °C
Operating humidity : Non-condensing (<10>
Protection class : IEC 60529: IP30 (jaw closed)
Operating altitude : 2000 m
Storage altitude : 12000 m
Current sensor action category : IEC 61557-13: Class 2, ≤30 A / m
Electromagnetic compatibility (EMC)
International
IEC 61326-1 : Industrial Electromagnetic Environment
CISPR 11 : Group 1 Class B
Group 1 : Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.
Class B : Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements. Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A : This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment. USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Included : Leakage Clamp Meter, Soft case, Safety Manual, Batteries: 2 AA
===========================================================
UNTUK MENGHINDARI PESANAN BARANG ANDA DITOLAK OLEH KAMI, SILAHKAN BERTANYA STOCK BARANG TERLEBIH DAHULU. TERIMA KASIH
Untuk informasi dan pemesanan, silahkan menghubungi :
Telp. & WA : 62.813.3117.0440
Mail : asiaindustri@gmail.com
============================================================
Empty
Packaging & Delivery
Empty too
Asia Industri
Perumahan Mahkota Simprug Blok B14 No.6, RT.004/RW.016,…
BANTEN